The physics of laser cleaning.
What the beam does at the surface, and how we choose the parameters.
- Source
- Pulsed fiber, MOPA
- Wavelength
- 1064 nm
- Pulse
- Nanosecond, selectable width
- Delivery
- Galvo-scanned, F-theta focus
- Controls
- Class 4 · ANSI Z136.1
01 · Mechanism
Ablation, not abrasion.
Each pulse sits on the contaminant for nanoseconds. Oxides and most paints absorb 1064 nm far better than bright metal. They heat in that time and leave by vaporization, spallation and the pressure of the expanding plume. Thin, clear films go as the surface under them heats.
Bare steel and aluminum reflect far more of the same light. Once a layer is gone, less energy couples into the metal below. That contrast, together with the layer’s lower ablation threshold, is what makes the process selective.
The job is to sit inside that window: enough fluence to clear the layer, not enough to change the substrate.
02 · Source
Why a MOPA source.
In a Q-switched fiber laser, pulse width moves with repetition rate. A MOPA seeds the amplifier with an electrically shaped pulse, so width and rate are set largely independently.
That gives us two levers instead of one. Short pulses for thin films and heat-sensitive parts. Longer pulses for heavier oxide and scale. Repetition rate then sets the overlap at the scan speed the part needs.
03 · Parameters
The parameters we actually control.
| Parameter | What it sets | What we watch |
|---|---|---|
| Fluence | Energy per area at the spot. It must clear the layer’s ablation threshold and stay under the substrate’s. | Color and texture of the cleared metal. Any frosting or melt means too far. |
| Pulse width | How long each pulse lasts. It sets peak power and how far heat travels. | Heat tint at the edges of the cleared area. |
| Repetition rate | Pulses per second. With scan speed, it sets overlap and energy per pulse. | Banding, or uncleared dots between pulses. |
| Scan speed and hatch | How the spot walks across the surface, line by line. | Even removal across the whole field. |
| Passes | Several light passes, or fewer heavy ones. | Part temperature between passes. |
| Focus and angle | Spot size and coupling on real, uneven parts. | Working distance on curves and edges. |
The working relationships
- F = Eₚ / πr²
- Average fluence
- Pₚₖ ≈ Eₚ / τ
- Peak power
- O = 1 − v / (f·d)
- Spot overlap
- L ≈ 2√(κτ)
- Heat diffusion length
Eₚ pulse energy · r spot radius · τ pulse width · v scan speed · f repetition rate · d spot diameter · κ thermal diffusivity
04 · Heat
Heat goes where the physics says.
Per pulse, heat travels micrometers. At tens to hundreds of thousands of pulses a second, it adds up.
That’s why we watch part temperature, not just the pulse math.
| Material | κ (m²/s) | 10 ns | 100 ns |
|---|---|---|---|
| Carbon steel (1020) | ≈ 1.4 × 10⁻⁵ | ≈ 0.7 µm | ≈ 2.4 µm |
| Stainless (304) | ≈ 4.2 × 10⁻⁶ | ≈ 0.4 µm | ≈ 1.3 µm |
| Aluminum (6061-T6) | ≈ 6.4 × 10⁻⁵ | ≈ 1.6 µm | ≈ 5.1 µm |
Thermal diffusion length, L ≈ 2√(κτ), from handbook diffusivities at room temperature. Estimates for orientation, not measurements.
05 · Fit
Where pulsed fiber fits.
At its best where precision, selectivity and access matter: defined areas, edges, features, and parts that can’t move.
For very large open areas, other methods can be faster. When that’s the case, we’ll say so.